Elabscience – Flow cytometry antibodies

 

Elabscience specializes in immunodiagnostic technology for life science community. We have complete platforms for R&D and manufacture. At the same time, we have in house QC for every product, endeavoring to keep your experiment results more consistent and precise.

Here is introduction of Elabscience’s flow cytometry antibodies.

Please visit our product dabase for detail of the flow cytometry antibodies.

 

How to choose flow cytometry antibodies?

Choosing high-quality and reliable fluorescent antibodies ensures the smooth running of flow cytometry and data analysis, especially multi-color flow cytometry that needs high resolution for color compensation. How to choose superior fluorescent antibodies for flow cytometry? Here are some key factors.

Three key factors

1, Commonly used clone numbers

There are usually several monoclonal antibodies with different clone numbers for a specific CD (clusters of differentiation) molecule. The more frequently the clone is used in flow cytometry, the more chance that you accomplish the experiments smoothly.

2, High SI (Staining Index)

High SI ensures good separation of the positive and negative cell populations, especially in experiments that need high resolution.

3, Low background binding

Though isotype antibodies or blocking reagents are usually used, sub-optimal conjugation of fluorescent dyes with antibodies significantly aggravate the background binding, especially with antibodies labeled by labeling kit without purification. Low background binding makes it much easier to determine the positive cell population from the negative one.

 

Why choose Elabscience flow cytometry antibodies?

1, Elabscience has selected commpnly used clones as antibodiy source for flow cytometry

We have antibodies of six colors now and many more are on the way.

2, Elabscience flow cytometry antibodies have considerable SI (staining index)

Table1. Comaprison of SI of Elabscience flow cytometry antibodies with other manufacturs.

3, Elabscience flow cytometry antibodies have low background binding

With optimized conjugation technologym, our flow cytometry antibodies can work with unstained cells instead of negative isotype control.

Human blood lymphocytes stained with PE conjugated anti-human CD8a antibody. The negative population (empty blue curve) has nearly the same fluorescence level of the unstained cell (filled red curve).

Please contact us for any inquiries, questions, or information requests.